FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4
918-988
WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury, property damage, or loss
of life. Refer to this manual. For assistance or additional
information consult an authorized installer, service agency
or the gas supplier.
FOR YOUR SAFETY:
Do not store or use gasoline or other ammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized
installer, service agency or the gas supplier.
FOR YOUR SAFETY:
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
11/15/12
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
HZI234E Gas Insert
Owners & Installation Manual
MODELS: HZI234E-NG Natural Gas HZI234E-LP Propane
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - HZI234E Gas Insert

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4918-988WARNING: Improper installation, adjustment, alteration

Page 2 - REGENCY GAS FIREPLACE INSERT

10Regency® HZI234E Direct Vent Gas InsertINSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe FPI Direct Vent Gas Insert must be installed in acco

Page 3 - TABLE OF CONTENTS

Regency® HZI234E Direct Vent Gas Insert11INSTALLATION11) Due to high temperatures, the appliance should be located out of high traffi c areas and away

Page 4 - SAFETY LABELSAFETY LABEL

12Regency® HZI234E Direct Vent Gas InsertINSTALLATIONMINIMUM CLEARANCES TO COMBUSTIBLES Side Walls A 8" (203 mm)* Cei

Page 5 - REQUIREMENTS

Regency® HZI234E Direct Vent Gas Insert13INSTALLATIONTHE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLI

Page 6 - DIMENSIONS

14Regency® HZI234E Direct Vent Gas InsertINSTALLATIONCONVERTING FROM 3" & 3" VENTING TO 3" & 2"1) Remove the top plate fr

Page 7

Regency® HZI234E Direct Vent Gas Insert15INSTALLATIONGAS INSERT AERATION SYSTEMThe burner aeration is factory set but may need adjusting due to either

Page 8

16Regency® HZI234E Direct Vent Gas InsertINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas sup-ply piping system by clo

Page 9

Regency® HZI234E Direct Vent Gas Insert17INSTALLATIONTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTERIF IN DOUBT DO NOT DO THIS CONVERSION !!Eac

Page 10 - INSTALLATION

18Regency® HZI234E Direct Vent Gas InsertINSTALLATION8) Remove the burner by removing 3 screws.9) Slide burner forward and lift up and out.16) Rein

Page 11

Regency® HZI234E Direct Vent Gas Insert19INSTALLATION3) Attach the label “This unit has been converted to LPG” near or on top of the serial # decal.4

Page 12

2Regency® HZI234E Direct Vent Gas InsertREGENCY GAS FIREPLACE INSERTTO THE NEW OWNERCongratulations! You are the owner of a state-of-the-art Gas Inse

Page 13

20Regency® HZI234E Direct Vent Gas InsertINSTALLATIONGLASS CRYSTALS OR OPTIONAL CERAMIC STONESINSTALLATION ON BURNERGlass Crystals shown on BurnerFor

Page 14

Regency® HZI234E Direct Vent Gas Insert21INSTALLATIONOPTIONAL PEBBLE / CRYSTAL INSTALLATIONFOR FIREBOX BASENatural River Pebbles shown surrounding the

Page 15

22Regency® HZI234E Direct Vent Gas InsertINSTALLATIONREFLECTIVE PANEL INSTALLATION1) Remove the faceplate and glass door if already installed - see

Page 16

Regency® HZI234E Direct Vent Gas Insert23INSTALLATIONGLASS DOOR REMOVAL / INSTALLATIONOPTIONAL SCREEN DOOR REMOVAL / INSTALLATION1) Remove the glass

Page 17

24Regency® HZI234E Direct Vent Gas InsertINSTALLATIONLOW PROFILE FACEPLATE INSTALLATION(3 AND 4 SIDED)1) Install 4 screws on sides of unit - in locat

Page 18

Regency® HZI234E Direct Vent Gas Insert25INSTALLATION11) Hook the front faceplate over the installed backing plate.12) Install the bottom louver by

Page 19

26Regency® HZI234E Direct Vent Gas InsertINSTALLATIONCONTOUR & CONTEMPORARY FACEPLATEFaceplate Contents List:1 Faceplate (Contour or Contemporary

Page 20

Regency® HZI234E Direct Vent Gas Insert27INSTALLATION7) Secure the loose wires into the wire clips above and to the bottom left of the battery pack a

Page 21

28Regency® HZI234E Direct Vent Gas InsertINSTALLATIONDiagram 1113) Re-install the remote receiver bracket (reverse step 10).14) Close the left side fa

Page 22

Regency® HZI234E Direct Vent Gas Insert29INSTALLATIONOPTIONAL BACKING PLATE3) Attach the top piece of the backing plate to the faceplate using 5 scre

Page 23

Regency® HZI234E Direct Vent Gas Insert33TABLE OF CONTENTSSAFETY LABELCopy of safety decal...4REQUI

Page 24

30Regency® HZI234E Direct Vent Gas InsertINSTALLATIONAttach Left & Right Backing Plate to Faceplate7) Align the screw holes on the left and right

Page 25

Regency® HZI234E Direct Vent Gas Insert31INSTALLATIONOPTIONAL HEARTH TRIM-CONTOUR/STANDARD FACEPLATE1) Open the left and right side faceplate panels.

Page 26

32Regency® HZI234E Direct Vent Gas InsertINSTALLATIONOPTIONAL HEARTH TRIM - LOW PROFILE FACEPLATE1) Align the screw holes on the hearth trim with the

Page 27

Regency® HZI234E Direct Vent Gas Insert33INSTALLATIONPROFLAME REMOTE CONTROL RECEIVER INSTALLATION1) Remove faceplate if installed.2) From the rig

Page 28

34Regency® HZI234E Direct Vent Gas InsertINSTALLATION6) Connect the wire harness to the back of the remote receiver; Place wire clip holder on the

Page 29

Regency® HZI234E Direct Vent Gas Insert35INSTALLATIONCAUTIONDo not wire millivolt Thermostat wiresto 120V wire.Thermostat Wire TableRecommended Maximu

Page 30

36Regency® HZI234E Direct Vent Gas InsertINSTALLATIONWIRING DIAGRAMThis heater does not require a 120V A.C. supply for operation. In case of a power f

Page 31

Regency® HZI234E Direct Vent Gas Insert37INSTALLATIONAn optional AC power adaptor may be installed as a constant power source for the SureFire system.

Page 32

38Regency® HZI234E Direct Vent Gas InsertINSTALLATIONFAN WIRING DIAGRAMCAUTION: Label all wires prior to disconnection when servicing controls. Wiring

Page 33

Regency® HZI234E Direct Vent Gas Insert3939INSTALLATIONOPERATING INSTRUCTIONSOPERATING INSTRUCTIONS1) Read and understand these instructions before o

Page 34

4Regency® HZI234E Direct Vent Gas Insert4SAFETY LABELSAFETY LABELThis is a copy of the labels that accompany each HZI234E Gas Insert. We have printed

Page 35

40Regency® HZI234E Direct Vent Gas Insert40OPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONS918-628bA) This appliance is equipped with an ig

Page 36

Regency® HZI234E Direct Vent Gas Insert41MAINTENANCE2) Remove the Termination Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or ot

Page 37

42Regency® HZI234E Direct Vent Gas InsertMAINTENANCEFAN REPLACEMENT1) Unplug the power source.2) Open the left and right side faceplate panels.3) R

Page 38

Regency® HZI234E Direct Vent Gas Insert43MAINTENANCEGround WireFan Cover Plate Removal13) Remove 13 screws to remove the fan access plate.14) Lift

Page 39 - OPERATING INSTRUCTIONS

44Regency® HZI234E Direct Vent Gas InsertMAINTENANCE1) Shut off gas supply to unit and unplug the power source by disconnecting the batteries.2) Ope

Page 40

Regency® HZI234E Direct Vent Gas Insert45PARTS LIST1 536-016 Door Frame2 536-517/P Fan Assembly3 536-532 Flue adaptor Assy4 536-539 Door Frame Assy5 5

Page 41 - MAINTENANCE

46Regency® HZI234E Direct Vent Gas InsertPARTS LIST3 AND 4 SIDED LOW PROFILE FACEPLATE ASSEMBLY Part # Description 1 566-924 3 sid

Page 42

Regency® HZI234E Direct Vent Gas Insert47PARTS LISTFACEPLATE ASSEMBLY Part # Description

Page 43

48Regency® HZI234E Direct Vent Gas InsertPARTS LISTBACKING PLATE & HEARTH TRIM ASSEMBLY Part # Description 53

Page 44

Regency® HZI234E Direct Vent Gas Insert49NOTES

Page 45 - PARTS LIST

Regency® HZI234E Direct Vent Gas Insert5REQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional req

Page 46

50Regency® HZI234E Direct Vent Gas InsertNOTES

Page 47

Regency® HZI234E Direct Vent Gas Insert51WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addition, our int

Page 48

Printed in CanadaRegency and Horizon are trademarks of FPI Fireplace Products International Ltd.© Copyright 2011, FPI Fireplace Products International

Page 49

6Regency® HZI234E Direct Vent Gas InsertDIMENSIONS20"510mm2918"739mm3278"836mm21532mm2278"581mm1"3"26mm[76mm]16"428

Page 50

Regency® HZI234E Direct Vent Gas Insert7DIMENSIONSDIMENSIONS W/ LOW PROFILE 4 SIDED FACEPLATE20"510mm2918"739mm3278"836mm3014"770m

Page 51 - WARRANTY

8Regency® HZI234E Direct Vent Gas InsertDIMENSIONS60°Contour FaceplateEIContemporary Faceplate27-3/4” (705mm)27-1/2” (699mm)19-1/2” (495mm)13” (330mm)

Page 52 - warranty online

Regency® HZI234E Direct Vent Gas Insert9INSTALLATIONCLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. CHILDREN AND