Regency Fireplace Products PG33-LPG Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Poêles Regency Fireplace Products PG33-LPG. Regency Fireplace Products PG33-LPG Operating instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
05/26/06
Freestanding Gas Stove
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation consult an authorized installer, serv-
ice agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flamma-
ble vapours and liquids in the vicinity of this
or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Owners &
Installation
Manual
LISTINGS AND CODE APPROVALS
These gas appliances have been tested
in accordance with AS4553-2000, NZS
5262 and have been certified by the
Australian Gas Association for
installation and operation as described
in these Installation and Operating
Instructions.
Your unit should be serviced
annually by an authorised service
person.
918-318a
Models: FG37-NG
FG37-LPG
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - Freestanding Gas Stove

05/26/06Freestanding Gas StoveFOR YOUR SAFETYWhat to do if you smell gas:Do not try to light any appli-anceDo not touch any electricalswitch: do not

Page 2

10 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterINSTALLATIONDiagram 2HORIZONTAL INSTALLATIONSDiagram 1*Dia 2: Local codes or regulat

Page 3 - TABLE OF CONTENTS

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 11Diagram 5Diagram 4Below Grade Snorkel InstallationIf the Snorkel Termination must b

Page 4 - DATA PLATE

12 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterSystem Data - FG37Burner Inlet Orifice Sizes: NG #37LPG #52Max. Input Rating

Page 5

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 13INSTALLATIONConversion Kit for NG to LPG Model #516-969THIS CONVERSION MUST BE DON

Page 6

14 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterInstaller Notice:These instructions must be left withthe appliance.Minimum pressure:

Page 7

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 15INSTALLATIONC)02-44AERATIONADJUSTMENTThe burner aeration is factory set but may needadju

Page 8

16 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterDiagram 2Diagram 34) The latches should already be at theproper setting. If the

Page 9

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 17INSTALLATION LOUVREINSTALLATIONAttach the top & bottom louvres to the side stovepane

Page 10 - INSTALLATION

18 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterFINAL CHECKBefore leaving this unit with the customer, theinstaller must ensure that the

Page 11

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 19OPERATING INSTRUCTIONSFIRST FIREThe FIRST FIRE in your heater is part of the paintcurin

Page 12

2 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterTo the New Owner:Congratulations! You are the owner of a state-of-the-art Regency Rear F

Page 13

20 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterNORMAL OPERATINGSOUNDS OFGAS APPLIANCESIt is possible that you will hear some

Page 14

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 21COPY OF THE LIGHTING PLATE INSTRUCTIONSOPERATING INSTRUCTIONSWARNING:DO NOT SPRAY A

Page 15

22 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterMAINTENANCECAUTION: ANY SAFETY SCREENOR GUARD REMOVED FOR SERV-ICING AN APPLIANCE MUST

Page 16

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 23LATCH ADJUSTMENTThe door latch may require adjustment as thedoor gasket material compr

Page 17

24 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterMAINTENANCEFAN MAINTENANCEIf your fan requires maintenance or replace-ment it m

Page 18

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 25MAINTENANCE4) Remove the two outside frame pieces byremoving two screws per sid

Page 19 - OPERATING INSTRUCTIONS

26 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterFG37 FG38 FG39 PG33 PG36 HG35 PG121/PG131910-915910-082910

Page 20

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 27PARTS LIST1) 560-920 Louvre Assy (Set) - Gold560-922 Louvre Assy (Set) - Black4)

Page 21

28 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterFG37 BURNER & LOG ASSEMBLY52) 910-190 Piezo Ignitor & Nut54) 910-373 Knob - Pilo

Page 22 - MAINTENANCE

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 29FG37 DOOR ASSEMBLIES Part # DescriptionPARTS LIST730-924 Gold Mitred Door

Page 23

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 3TABLE OF CONTENTS Page PageOperating InstructionsOperating Instructions ...

Page 24

30 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater________________________________________________________________________________________

Page 25

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 31WARRANTYExclusions:This limited Lifetime Warranty does not extend to or includepaint, do

Page 26 - PARTS LIST

Printed in Canada© Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.

Page 27

4 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterThis is a copy of the label that accompanieseach REGENCY Rear Flued Room Sealed F

Page 28

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 5INSTALLATION AND REPAIRSSHOULD BE DONE BY AN AUTHOR-IZED SERVICE PERSON. THIS AP-PLIANC

Page 29

6 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater14) Under no circumstances should any solidfuels (wood, paper, cardboard, coal, etc

Page 30

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 7INSTALLATIONEXTERIOR FLUE TERMINATION LOCATIONSMinimum clearances required for balance

Page 31 - WARRANTY

8 FG37 Regency Rear Flued Room Sealed Freestanding Gas HeaterPLANNING YOUR FLUING INSTALLATIONINSTALLATIONFLUINGThe Regency Room Sealed System (Horizo

Page 32 - Printed in Canada

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 9INSTALLATIONFLUING ARRANGEMENTS - VERTICAL TERMINATIONSFOR BOTH RESIDENTIAL &